Five services, bought separately or together. Every utility we serve has a different mix, and most started with one and added another.
Throughout, one rule applies: the utility sets the limits and signs them. Operators work inside those limits, and every action they take is logged with the time and the person.
24/7 Monitoring
Alarm watch for pump stations, tanks and plants, with call-out to the utility's on-call crew.
Each site sends its alarms and a set of readings to our control room over a cellular or radio link. An operator acknowledges the alarm, checks the related readings, and decides whether it needs a crew. If it does, the operator calls the person on the utility's on-call list, in the order the utility gave us, and stays on the alarm until someone confirms they have it.
- Alarm limits and call-out order are written down per site and reviewed with the utility every year.
- Operators work from a screen for each site showing its tanks, pumps and treatment readings.
- A handover note passes between shifts, so nothing depends on one person's memory.
Operated Service
Control-room operators run pumps and set levels within limits the utility signs off, and log every action.
This is for utilities that want the pumps run, not only watched. A lift station fills and empties through the day; a booster station swaps its lead pump on a schedule; a plant follows demand. Our operators take care of the routine, inside limits such as wet-well level bands, pump run-time and tank ranges. Anything outside those limits goes to the utility's crew.
- Limits are agreed in a short signed document, one per site.
- Controllers refuse changes that break an interlock, whoever asks.
- Every setpoint change, start and stop is logged, and the utility can request the log at any time.
Telemetry Upgrades
Replacement of radio and dial-up links with cellular site gateways and encrypted tunnels.
Many small sites still report over licensed radio or a dial-up line that the carrier is retiring. We replace those links with a cellular gateway at the site and an encrypted tunnel back to our control room. We do the work one site at a time and keep the old link in place until the new one has run through a full cycle of the site's alarms and readings.
- Firmware changes on site gateways are staged: one site first, then the rest.
- Each upgrade ends with a written test record of every alarm and reading, signed off with the utility.
Compliance Reporting
Monthly operating reports built from the historian for the utility's regulator submissions.
Readings are stored in a historian at our operations center. Once a month we build the operating report from that record: flows, residuals, run-times, alarms and the actions taken. The utility reviews it and submits it. If a gap in the data needs explaining, the report says so.
Controls Engineering
Controller programming, screen changes and commissioning support for small sites.
Our controls engineers work on small sites where a full integrator would be out of proportion: a new pump, a replaced drive, a changed screen, a tank level that needs a second transmitter. Field technicians do the site visits. Engineers keep controller backups and the drawings that go with them.
How an engagement starts
- A conversation about the sites, the current alarms and who gets called.
- A site walk and a written proposal with a fixed monthly price.
- Limits and call-out orders agreed and signed.
- A parallel run: our control room watches alongside the utility for a period before taking over any night shift.
To start, write to hello@packet.tech.